Home » Products » Water Loop Heat Pump » Split European Fan Coil Units

Split European Fan Coil Units

Model Outdoor VWLN 025W VWLN 028W VWLN 032W VWLN 044W VWLN 050W VWLN 062W VWLN 078W VWNL 088W VWLN 095W VWLN 110W VWLN 130W
Indoor VWLN 025E VWLN 028E VWLN 032E VWLN 044E VWLN 050E VWLN 062E VWLN 078E VWLN 088E VWLN 095E VWLN 110E VWLN 130E
Nominal Cooling Capacity kW 2.42 2.81 3.14 4.35 5.01 6.16 7.79 8.8 9.51 10.7 13.19
Nominal Heating Capacity kW 2.66 3.09 3.45 4.79 5.51 6.78 8.57 9.68 10.46 11.77 14.51
Nominal Air Flow m3/h 450 500 560 780 900 1100 1400 1600 1700 1930 2400
CFM 265 294 329 459 529 647 824 941 1000 1135 1412
Static Pressure Pa 0 0 0 30 30 30 30 30 30 30 50
Power Cooling Input W 620 700 800 1100 1240 1530 1940 2200 2000 2300 2840
Power Heating Input W 645 730 830 1150 1300 1600 2020 2080 2290 2390 2980
Rated Cooling Current A 3.1 3.5 4 5.5 6.2 7.65 9.7 10 11 11.5 5.7
Rated Heating Current A 3.2 3.7 4.2 5.8 6.5 8.0 10.1 10.4 11.5 12.0 5.9
Refrigerant Type R22
Compressor Rotator Scroll
Outdoor Condenser Water Flow m3/h 0.52 0.60 0.68 0.94 1.08 1.47 1.67 1.89 1.98 2.43 2.76
Water Pressure kPa 12 23 45 21 27 40 42 40 45 68 40
Inlet/Outlet Pipes   Rc1/2 Rc1/2 Rc1/2 Rc3/4 Rc3/4 Rc3/4 Rc3/4 Rc3/4 Rc3/4 Rc3/4 Rc3/4
Types   Tube in tube heat exchanger
Dimensions (mm) L 560 560 560 560 560 560 560 698 698 698 698
W 289 289 289 289 289 289 289 367 367 367 367
H 360 360 360 418 418 418 500 500 500 500 500
Weight kg 26 28 30 34 36 40 60 62 64 71 76
Power Supply V/pH/Hz 220V/1pH/50HZ 380V/ 3pH/ 50HZ
Indoor Units Dimensions (mm) L 908 958 1058 1058 1058 1308 1908 1908 1908 2008 2008
W 235 235 235 235 235 235 235 235 235 235 235
H 473 473 473 473 473 473 473 473 473 473 473
Weight kg 23 24 25 26 28 30 37 41 42 43 48
Power Supply V/pH/Hz 220V/1pH/50HZ
Condenser Pipe in R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2
Pipe Dimensions Liquor Φmm 6.35 6.35 6.35 6.35 6.35 9.52 9.52 9.52 12.7 12.7 12.7
Air Φmm 9.52 9.52 9.52 12.7 12.7 15.88 15.88 15.88 19.05 19.05 19.05

Note
1. Noise data is measured in semi-anechoic rooms according to the relative national system requirements.
2. Nominal cooling capacity is measured in condition: Indoor D.B.: t(d)=27℃ W.B.: t (w)= 19℃; water inlet temperature: t=30℃; water outlet temperature: t= 35℃. Nominal heating capacity is measured in condition: Indoor D.B.: t(d)=20℃ W.B.: t(w)=15℃; water inlet temperature: t=20℃.
3. Standard data will be varied with products improving, please take the data marked on nameplates of units as standard